A compact X-ray source, based on a 5 MeV autofocusing electron linac, has been designed and set up for radiographic purposes at the Dipartimento di Fisica, Università di Messina. A detailed study has been performed, by means of the MCNP-4C2 code, on the optimization of the parameters involved in the X-ray production, transport and detection, that will be described in this paper, as well as the final source configuration pattern.

Design of a 5 MeV electron linac based X-ray source

AUDITORE, Lucrezia;BARNA', Calogero;DE PASQUALE, Domenico;ITALIANO A;LORIA, DARIO;TRIFIRO', ANTONIO;TRIMARCHI, MARINA
2005-01-01

Abstract

A compact X-ray source, based on a 5 MeV autofocusing electron linac, has been designed and set up for radiographic purposes at the Dipartimento di Fisica, Università di Messina. A detailed study has been performed, by means of the MCNP-4C2 code, on the optimization of the parameters involved in the X-ray production, transport and detection, that will be described in this paper, as well as the final source configuration pattern.
2005
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/1419959
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact