Although comprehensive two-dimensional gas chromatography (GC x GC) has been on the scene for more than 15 years, it is still generally considered a relatively novel technique and is yet far from being fully established. The revolutionary aspect of GC x GC, with respect to classical multidimensional chromatography, is that the entire sample is subjected to two distinct analytical separations. The resulting enhanced separating capacity makes this approach a prime choice when GC analysts are challenged with highly complex mixtures. The combination of a third mass spectrometric dimension to a GC x GC system generates the most powerful analytical tool today for volatile and semi-volatile analytes. The present review is focused on the rather brief but not scant, history of comprehensive two-dimensional GC-MS: the first experiments were carried out at the end of the 1990s and, since then, the methodology has been increasingly studied and applied. Almost all GC x GC-MS applications have been carried out by using either a time-of-flight or quadrupole mass analyzer; significant experiments relative to a variety of research fields, as well as advantages and disadvantages of the MS systems employed, are discussed. The principles, practical and theoretical aspects, and the most significant developments of GC x GC are also described.

Comprehensive two-dimensional gas chromatography-mass spectrometry: A review

MONDELLO, Luigi;TRANCHIDA, Peter Quinto;DUGO, Paola;DUGO, Giovanni
2008-01-01

Abstract

Although comprehensive two-dimensional gas chromatography (GC x GC) has been on the scene for more than 15 years, it is still generally considered a relatively novel technique and is yet far from being fully established. The revolutionary aspect of GC x GC, with respect to classical multidimensional chromatography, is that the entire sample is subjected to two distinct analytical separations. The resulting enhanced separating capacity makes this approach a prime choice when GC analysts are challenged with highly complex mixtures. The combination of a third mass spectrometric dimension to a GC x GC system generates the most powerful analytical tool today for volatile and semi-volatile analytes. The present review is focused on the rather brief but not scant, history of comprehensive two-dimensional GC-MS: the first experiments were carried out at the end of the 1990s and, since then, the methodology has been increasingly studied and applied. Almost all GC x GC-MS applications have been carried out by using either a time-of-flight or quadrupole mass analyzer; significant experiments relative to a variety of research fields, as well as advantages and disadvantages of the MS systems employed, are discussed. The principles, practical and theoretical aspects, and the most significant developments of GC x GC are also described.
2008
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/1833917
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 20
  • Scopus 343
  • ???jsp.display-item.citation.isi??? 302
social impact