In the present work, a novel strategy including the use of two different comprehensive HPLC methods has been employed to study the whole carotenoid composition of mandarin essential oil. Thus, two different fully orthogonal two-dimensional HPLC methods have been used. A silica microbore column was coupled to a C-18 monolithic column to study the mandarin saponified extract, while the coupling of a cyano microbore column to a C-18 monolithic column was employed to study the intact mandarin essential oil sample in order to characterize the native carotenoid esters composition. Detection was performed by connecting a photodiode array detection (DAD) system in parallel with a MS detection system operated with an atmospheric pressure chemical ionization (APCI) interface. Thus, the carotenoid identification was carried out by combining the information provided by the DAD and MS systems and the peaks relative position in the two-dimensional chromatograms.

Comprehensive normal-phase x reversed-phase liquid chromatography coupled to photodiode array and mass spectrometry detection for the analysis of free carotenoids and carotenoid esters from mandarin

DUGO, Paola;GIUFFRIDA, Daniele;DUGO, Giovanni;MONDELLO, Luigi
2008-01-01

Abstract

In the present work, a novel strategy including the use of two different comprehensive HPLC methods has been employed to study the whole carotenoid composition of mandarin essential oil. Thus, two different fully orthogonal two-dimensional HPLC methods have been used. A silica microbore column was coupled to a C-18 monolithic column to study the mandarin saponified extract, while the coupling of a cyano microbore column to a C-18 monolithic column was employed to study the intact mandarin essential oil sample in order to characterize the native carotenoid esters composition. Detection was performed by connecting a photodiode array detection (DAD) system in parallel with a MS detection system operated with an atmospheric pressure chemical ionization (APCI) interface. Thus, the carotenoid identification was carried out by combining the information provided by the DAD and MS systems and the peaks relative position in the two-dimensional chromatograms.
2008
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/1836427
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 82
  • ???jsp.display-item.citation.isi??? 69
social impact