The purpose of this research was to develop a sensitive and accurate chronopotentiometric method at a gold film electrode, to determine trace and ultra trace levels of As(III) and As(V) in alimentary and environmental water systems. As(III) was directly determined in the aqueous matrix at a deposition potential of 300 mV for 180 s and at a constant anodic current of 2.5 lA, without any sample pre-treatment; moreover the chronopotentiometric method did not require a time-consuming de-oxygenation step prior to the analysis. A 3M HCl solution was chosen as the best stripping medium. The direct analysis of As(V) required the application of a high negative over-potential and, thus, measurements were characterized by poor reproducibility; therefore As(V) was determined after reduction to As(III) with KI in a strong hydrochloric acid solution. Under the optimised electrochemical conditions, detection limits of 0.08 lg As(III) l1 were achieved and no significant interferences from Cd, Cu, Pb, Zn and organic substances were observed. As(V) was the most abundant species in all the studied environmental and alimentary aqueous matrices. Amongst the beverages, tea and coffee presented the As(V) highest concentration ranges (934–1740 lg l1 and 850–1290 lg l1, respectively) while bottled mineral water the lowest (<1.61 lg l1); whereas As(III) levels lower than 5.0 lg l1 were detected only in wine samples.

Speciation of inorganic arsenic in alimentary and environmental aqueous samples by using derivative anodic stripping chronopotentiometry (dASCP)

DUGO, Giacomo;LO TURCO, Vincenzo;DI BELLA, GIUSEPPA
2005-01-01

Abstract

The purpose of this research was to develop a sensitive and accurate chronopotentiometric method at a gold film electrode, to determine trace and ultra trace levels of As(III) and As(V) in alimentary and environmental water systems. As(III) was directly determined in the aqueous matrix at a deposition potential of 300 mV for 180 s and at a constant anodic current of 2.5 lA, without any sample pre-treatment; moreover the chronopotentiometric method did not require a time-consuming de-oxygenation step prior to the analysis. A 3M HCl solution was chosen as the best stripping medium. The direct analysis of As(V) required the application of a high negative over-potential and, thus, measurements were characterized by poor reproducibility; therefore As(V) was determined after reduction to As(III) with KI in a strong hydrochloric acid solution. Under the optimised electrochemical conditions, detection limits of 0.08 lg As(III) l1 were achieved and no significant interferences from Cd, Cu, Pb, Zn and organic substances were observed. As(V) was the most abundant species in all the studied environmental and alimentary aqueous matrices. Amongst the beverages, tea and coffee presented the As(V) highest concentration ranges (934–1740 lg l1 and 850–1290 lg l1, respectively) while bottled mineral water the lowest (<1.61 lg l1); whereas As(III) levels lower than 5.0 lg l1 were detected only in wine samples.
2005
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/1890194
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 31
social impact