The main objective of the herein described research was focused on performing satisfactory flow modulation (FM), in comprehensive two-dimensional gas chromatography-mass spectrometry (GC × GC-MS), using an MS-compatible second-dimension gas flow of approx. 4 mL min-1. The FM model used was based on that initially proposed by Seeley et al. [3]. The use of limited gas flows was enabled through fine tuning of the FM parameters, in particular the duration of the re-injection (or flushing) process. Specifically, the application of a long re-injection period (i.e., 700 ms) enabled efficient accumulation-loop flushing with gas flows of about 4 mL min-1. It was possible to apply such extended re-injection periods by using different restrictor lengths in the connections linking the modulator to the auxiliary pressure source. FM GC × GC-MS applications were performed on a mixture containing C9-10 alkanes, and on a sample of essential oil. GC × GC-MS sensitivity was compared with that attained by using conventional GC-MS analysis, in essential oil applications. It was observed that signal intensities were, in general, considerably higher in the FM GC × GC-MS experiments.
Flow modulation comprehensive two-dimensional gas chromatography-mass spectrometry using ≈ 4 mL min-1 gas flows
FRANCHINA, FLAVIO ANTONIO;MAIMONE, MARIAROSA;TRANCHIDA, Peter Quinto;MONDELLO, Luigi
2016-01-01
Abstract
The main objective of the herein described research was focused on performing satisfactory flow modulation (FM), in comprehensive two-dimensional gas chromatography-mass spectrometry (GC × GC-MS), using an MS-compatible second-dimension gas flow of approx. 4 mL min-1. The FM model used was based on that initially proposed by Seeley et al. [3]. The use of limited gas flows was enabled through fine tuning of the FM parameters, in particular the duration of the re-injection (or flushing) process. Specifically, the application of a long re-injection period (i.e., 700 ms) enabled efficient accumulation-loop flushing with gas flows of about 4 mL min-1. It was possible to apply such extended re-injection periods by using different restrictor lengths in the connections linking the modulator to the auxiliary pressure source. FM GC × GC-MS applications were performed on a mixture containing C9-10 alkanes, and on a sample of essential oil. GC × GC-MS sensitivity was compared with that attained by using conventional GC-MS analysis, in essential oil applications. It was observed that signal intensities were, in general, considerably higher in the FM GC × GC-MS experiments.File | Dimensione | Formato | |
---|---|---|---|
417 paper 13-16.pdf
solo utenti autorizzati
Tipologia:
Versione Editoriale (PDF)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.04 MB
Formato
Adobe PDF
|
1.04 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.