The present research is focused on the preliminary evaluation, in particular in relation to the advisable operational conditions, of a novel low duty cycle flow modulator. In such a respect, a fast comprehensive two-dimensional gas chromatography-mass spectrometry method is herein proposed. Applications on a C7-C30 series of alkanes, 64 fragrance allergens (plus 2 internal standards), and 5 perfumes, were carried out by using two different column sets, low-polarity + medium-polarity and low-polarity + low-polarity. In both cases, the first column was of dimensions 10 m × 0.25 mm ID × 0.25 µm df, while the second one was of dimensions 1 m × 0.10 mm ID × 0.10 µm df. A modulation period of 700 ms, with a re-injection period of 80 ms, was used in order to obtain a higher duty cycle (measured to be approx. 0.04). Absolute quantification of the allergens was carried out by using two internal standards, namely 1,4-dibromobenzene and 4,4'-dibromobiphenyl. In terms of limits of quantification the instrumental response was characterized by a wide variability, ranging between 9 ppb and 5.4 ppm for both column sets. A total number of 97 fragrance allergens were identified and quantified in five commercial perfumes.

PRELIMINARY OBSERVATIONS ON THE USE OF A NOVEL LOW DUTY CYCLE FLOW MODULATOR FOR COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY

Aloisi I.
Primo
;
Giocastro B.
Secondo
;
Ferracane A.;Salerno T. M. G.;Zoccali M.;Tranchida P. Q.
Penultimo
;
Mondello L.
Ultimo
2021-01-01

Abstract

The present research is focused on the preliminary evaluation, in particular in relation to the advisable operational conditions, of a novel low duty cycle flow modulator. In such a respect, a fast comprehensive two-dimensional gas chromatography-mass spectrometry method is herein proposed. Applications on a C7-C30 series of alkanes, 64 fragrance allergens (plus 2 internal standards), and 5 perfumes, were carried out by using two different column sets, low-polarity + medium-polarity and low-polarity + low-polarity. In both cases, the first column was of dimensions 10 m × 0.25 mm ID × 0.25 µm df, while the second one was of dimensions 1 m × 0.10 mm ID × 0.10 µm df. A modulation period of 700 ms, with a re-injection period of 80 ms, was used in order to obtain a higher duty cycle (measured to be approx. 0.04). Absolute quantification of the allergens was carried out by using two internal standards, namely 1,4-dibromobenzene and 4,4'-dibromobiphenyl. In terms of limits of quantification the instrumental response was characterized by a wide variability, ranging between 9 ppb and 5.4 ppm for both column sets. A total number of 97 fragrance allergens were identified and quantified in five commercial perfumes.
2021
File in questo prodotto:
File Dimensione Formato  
JCA.pdf

solo utenti autorizzati

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.4 MB
Formato Adobe PDF
1.4 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3200112
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact