The structural differences in (100)-, (110)- and (111)-oriented cubic yttria-stabilised zirconia (YSZ) single crystals after implantation with 2 MeV Si+ ions at the fluences of 5 × 1015, 1 × 1016 and 5 × 1016 cm−2 were studied using Rutherford backscattering spectrometry in the channelling mode (RBS-C), X-ray diffraction (XRD) and Raman spectroscopy. The RBS-C results show that the damage accumulation in the 〈110〉 direction exhibits a lower level of disorder (<0.3) than the other orientations (<0.6) and it seems that the (110) crystallographic orientation is the most resistant to radiation damage. The experimental results from the RBS measurement were compared with the results from the XRD measurements. The XRD data were analysed using the standard two-beam dynamical X-ray diffraction theory and the pure isotropic strain was deduced from the fit for the fluence of 5 × 1015 cm−2. It was shown that the maximum value of the isotropic strain does not depend on the surface orientation. The increase in signal intensity at ∼689 cm−1 is probably related to an increase in implantation defects such as oxygen vacancies.

Microstructural modifications induced in Si+ -implanted yttria-stabilised zirconia: a combined RBS-C, XRD and Raman investigation

M. Cutroneo
Co-primo
Project Administration
;
2022-01-01

Abstract

The structural differences in (100)-, (110)- and (111)-oriented cubic yttria-stabilised zirconia (YSZ) single crystals after implantation with 2 MeV Si+ ions at the fluences of 5 × 1015, 1 × 1016 and 5 × 1016 cm−2 were studied using Rutherford backscattering spectrometry in the channelling mode (RBS-C), X-ray diffraction (XRD) and Raman spectroscopy. The RBS-C results show that the damage accumulation in the 〈110〉 direction exhibits a lower level of disorder (<0.3) than the other orientations (<0.6) and it seems that the (110) crystallographic orientation is the most resistant to radiation damage. The experimental results from the RBS measurement were compared with the results from the XRD measurements. The XRD data were analysed using the standard two-beam dynamical X-ray diffraction theory and the pure isotropic strain was deduced from the fit for the fluence of 5 × 1015 cm−2. It was shown that the maximum value of the isotropic strain does not depend on the surface orientation. The increase in signal intensity at ∼689 cm−1 is probably related to an increase in implantation defects such as oxygen vacancies.
2022
Inglese
Inglese
ELETTRONICO
No
Si, OA ibrido
No
No
nessuno
24
10
6290
6301
sì
Internazionale
Esperti anonimi
Radiation damage, Silicon, Single crystals, X ray diffraction, Yttria stabilized zirconia, Yttrium oxide
sì
info:eu-repo/semantics/article
Mikšová, R.; Malinský, P.; Cutroneo, M.; Holý, V.; Sofer, Z.; Cajzl, J.; Debelle, A.; Nowicki, L.; Macková, A....espandi
14.a Contributo in Rivista::14.a.1 Articolo su rivista
9
262
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3345797
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact