The present research description is focused on the evaluation of a high-speed triple quadrupole mass spectrometer, carried out under moderately fast gas chromatography conditions (analysis time: 17 min). The mass spectrometric system is capable of operation under high-speed GC conditions, in both full-scan (maximum scan speed: 20,000 amu/s) and multiple reaction monitoring modalities. Furthermore, the triple quadrupole system can generate full scan and multiple reaction monitoring data simultaneously, also in a very rapid manner. A fast method was developed for the: (i) qualitative analysis of untargeted Citrus essential oil compounds, and (ii) the quali/quantitative analysis of targeted ones, namely three preservatives (o-phenylphenol, butylated hydroxytoluene, butylated hydroxy-anisole). The mass spectrometric system generated a more-than-sufficient number of data points/peak for both identification and quantification purposes. The level of sensitivity, reached through the multiple-reaction-monitoring side of the analysis, widely exceeded the requirements of current legislation. Method validation, related to the targeted analysis, was performed considering precision of retention times, peak areas and ion ratios; limits of detection/quantification, and accuracy were also measured. 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Fast gas chromatography combined with a high-speed triple quadrupole mass spectrometer for the analysis of unknown and target citrus essential oil volatiles.

TRANCHIDA, Peter Quinto;ZOCCALI, MARIOSIMONE;FRANCHINA, FLAVIO ANTONIO;BONACCORSI, Ivana Lidia;DUGO, Paola;MONDELLO, Luigi
2013-01-01

Abstract

The present research description is focused on the evaluation of a high-speed triple quadrupole mass spectrometer, carried out under moderately fast gas chromatography conditions (analysis time: 17 min). The mass spectrometric system is capable of operation under high-speed GC conditions, in both full-scan (maximum scan speed: 20,000 amu/s) and multiple reaction monitoring modalities. Furthermore, the triple quadrupole system can generate full scan and multiple reaction monitoring data simultaneously, also in a very rapid manner. A fast method was developed for the: (i) qualitative analysis of untargeted Citrus essential oil compounds, and (ii) the quali/quantitative analysis of targeted ones, namely three preservatives (o-phenylphenol, butylated hydroxytoluene, butylated hydroxy-anisole). The mass spectrometric system generated a more-than-sufficient number of data points/peak for both identification and quantification purposes. The level of sensitivity, reached through the multiple-reaction-monitoring side of the analysis, widely exceeded the requirements of current legislation. Method validation, related to the targeted analysis, was performed considering precision of retention times, peak areas and ion ratios; limits of detection/quantification, and accuracy were also measured. 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
2013
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/2523628
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
social impact