Enantiomeric separations were performed on five modified polysaccharide-based chiral stationary phases (CSPs) containing cellulose tris(3,5-dimethylphenylcarbamate) (Lux Cellulose-1), cellulose tris(3-chloro-4-methylphenylcarbamate) (Lux Cellulose-2), cellulose tris(4-methylbenzoate) (Lux Cellulose-3), cellulose tris(4-chloro-3-methylphenylcarbamate) (Lux Cellulose-4), amylose tris(5-chloro- 2-methylphenylcarbamate) (Lux Amylose-2) by high-performance liquid chromatography and evaporative light scattering detector. A method for direct separation of pairs of sn-1(3)-monoacylglycerols (MAGs) was established using n-hexane/2-propanol as the mobile phase. The washing of CSPs with mobile phases based on n-hexane/2-propanol, containing small amount of acids, improved considerably the efficiency of separations. Racemic mixtures of sn-1(3)-MAGs with different acyl chains could not be directly separated using only one of the columns tested; employing a tandem column system that consisted of a very short silver-loaded column connected downstream with Lux Cellulose-1 the method allowed, for the first time, the separation of four enantiomeric pairs of standard in a single chromatographic run.

Separation of racemic mixtures of sn-1(3)-monoacylglycerols by enantioselective-HPLC/ELSD

Fotia V
Primo
;
Potortì AG;La Torre GL;Di Bella G;Saitta M.
Ultimo
2021-01-01

Abstract

Enantiomeric separations were performed on five modified polysaccharide-based chiral stationary phases (CSPs) containing cellulose tris(3,5-dimethylphenylcarbamate) (Lux Cellulose-1), cellulose tris(3-chloro-4-methylphenylcarbamate) (Lux Cellulose-2), cellulose tris(4-methylbenzoate) (Lux Cellulose-3), cellulose tris(4-chloro-3-methylphenylcarbamate) (Lux Cellulose-4), amylose tris(5-chloro- 2-methylphenylcarbamate) (Lux Amylose-2) by high-performance liquid chromatography and evaporative light scattering detector. A method for direct separation of pairs of sn-1(3)-monoacylglycerols (MAGs) was established using n-hexane/2-propanol as the mobile phase. The washing of CSPs with mobile phases based on n-hexane/2-propanol, containing small amount of acids, improved considerably the efficiency of separations. Racemic mixtures of sn-1(3)-MAGs with different acyl chains could not be directly separated using only one of the columns tested; employing a tandem column system that consisted of a very short silver-loaded column connected downstream with Lux Cellulose-1 the method allowed, for the first time, the separation of four enantiomeric pairs of standard in a single chromatographic run.
2021
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3208279
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact