The present research can be considered as a proof-of-principle study focused on the determination of chiral pesticides using a supercritical fluid extraction instrument coupled on-line with an enantioselective supercritical fluid chromatography-triple quadrupole mass spectrometry. To the best of Authors’ knowledge, this is the first description of an on-line approach for the extraction and determination of chiral pesticides. Metalaxyl, benalaxyl and dimethenamid were investigated in nine hemp seed samples belonging to four varieties of Cannabis sativa; only in one case a pesticide was found at levels above the method limit of quantification (LoQ), though within the EU maximum residue level value. The figures-of-merit determined were linearity, precision, limit of detection (LoD), and LoQ. Regression coefficients were between 0.9856 and 0.9973, the LoDs were in the 0.04–0.41 μg kg−1 range, the LoQs were in the 0.12–1.38 μg kg−1 range, while coefficients of variation were between 1 and 3% (10 μg kg−1 level).

On-line coupling of supercritical fluid extraction with enantioselective supercritical fluid chromatography-triple quadrupole mass spectrometry for the determination of chiral pesticides in hemp seeds: A proof-of-principle study

Zoccali M.
Primo
;
Russo M.
Secondo
;
Testa Camillo M. R.;Salafia F.;Tranchida P. Q.;Dugo P.
Penultimo
;
Mondello L.
Ultimo
2022-01-01

Abstract

The present research can be considered as a proof-of-principle study focused on the determination of chiral pesticides using a supercritical fluid extraction instrument coupled on-line with an enantioselective supercritical fluid chromatography-triple quadrupole mass spectrometry. To the best of Authors’ knowledge, this is the first description of an on-line approach for the extraction and determination of chiral pesticides. Metalaxyl, benalaxyl and dimethenamid were investigated in nine hemp seed samples belonging to four varieties of Cannabis sativa; only in one case a pesticide was found at levels above the method limit of quantification (LoQ), though within the EU maximum residue level value. The figures-of-merit determined were linearity, precision, limit of detection (LoD), and LoQ. Regression coefficients were between 0.9856 and 0.9973, the LoDs were in the 0.04–0.41 μg kg−1 range, the LoQs were in the 0.12–1.38 μg kg−1 range, while coefficients of variation were between 1 and 3% (10 μg kg−1 level).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/3217976
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 5
social impact