The present research can be considered as a proof-of-principle study focused on the determination of chiral pesticides using a supercritical fluid extraction instrument coupled on-line with an enantioselective supercritical fluid chromatography-triple quadrupole mass spectrometry. To the best of Authors’ knowledge, this is the first description of an on-line approach for the extraction and determination of chiral pesticides. Metalaxyl, benalaxyl and dimethenamid were investigated in nine hemp seed samples belonging to four varieties of Cannabis sativa; only in one case a pesticide was found at levels above the method limit of quantification (LoQ), though within the EU maximum residue level value. The figures-of-merit determined were linearity, precision, limit of detection (LoD), and LoQ. Regression coefficients were between 0.9856 and 0.9973, the LoDs were in the 0.04–0.41 μg kg−1 range, the LoQs were in the 0.12–1.38 μg kg−1 range, while coefficients of variation were between 1 and 3% (10 μg kg−1 level).
On-line coupling of supercritical fluid extraction with enantioselective supercritical fluid chromatography-triple quadrupole mass spectrometry for the determination of chiral pesticides in hemp seeds: A proof-of-principle study
Zoccali M.Primo
;Russo M.
Secondo
;Testa Camillo M. R.;Salafia F.;Tranchida P. Q.;Dugo P.Penultimo
;Mondello L.Ultimo
2022-01-01
Abstract
The present research can be considered as a proof-of-principle study focused on the determination of chiral pesticides using a supercritical fluid extraction instrument coupled on-line with an enantioselective supercritical fluid chromatography-triple quadrupole mass spectrometry. To the best of Authors’ knowledge, this is the first description of an on-line approach for the extraction and determination of chiral pesticides. Metalaxyl, benalaxyl and dimethenamid were investigated in nine hemp seed samples belonging to four varieties of Cannabis sativa; only in one case a pesticide was found at levels above the method limit of quantification (LoQ), though within the EU maximum residue level value. The figures-of-merit determined were linearity, precision, limit of detection (LoD), and LoQ. Regression coefficients were between 0.9856 and 0.9973, the LoDs were in the 0.04–0.41 μg kg−1 range, the LoQs were in the 0.12–1.38 μg kg−1 range, while coefficients of variation were between 1 and 3% (10 μg kg−1 level).Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.