The present research is focused on the optimization of an automatized sample preparation and fast gas chromatography-mass spectrometry (GC-MS) method for the analysis of fatty acid methyl esters (FAMEs) in blood samples and dietary supplements, with the primary objective being a significant reduction of the analysis time and, hence, an enhanced sample throughput. The mass spectrometer was operated in the scan/selected ion monitoring (SIM) acquisition method, thus enabling the obtainment of qualitative and (highly sensitive) quantitative data. The separation of FAMEs was obtained in about 11 min by using a micro-bore column of dimensions 15 m x 0.10 mm ID x 0.10 mu m d(f) with a polyethylene glycol stationary phase. The novelty of the research involves reducing analysis time by using the novel fast GC-MS method with increased identification reliability and sensitivity in a single chromatographic run. With regard to the figures of merit, linearity, accuracy, and limits of detection (LoD) and quantification (LoQ) were determined. Specifically, regression coefficients were between 0.9901 and 0.9996; the LoDs ranged from 0.05 to 1.02 mu g g(-1) for the blood analysis method, and from 0.05 to 0.26 mg g(-1) in the case of the dietary supplement approach. With respect to LoQs, the values were in the ranges of 0.15-3.39 mu g g(-1) and 0.15-0.86 mg g(-1) for blood and dietary supplements analysis methods, respectively. Accuracy was evaluated by analyzing certified reference materials (human plasma, fish oil).
Automated sample preparation and fast GC-MS determination of fatty acids in blood samples and dietary supplements
Ferracane, AntonioPrimo
;Aloisi, IvanSecondo
;Galletta, Micaela;Zoccali, Mariosimone;Tranchida, Peter Q;Micalizzi, Giuseppe
Penultimo
;Mondello, LuigiUltimo
2022-01-01
Abstract
The present research is focused on the optimization of an automatized sample preparation and fast gas chromatography-mass spectrometry (GC-MS) method for the analysis of fatty acid methyl esters (FAMEs) in blood samples and dietary supplements, with the primary objective being a significant reduction of the analysis time and, hence, an enhanced sample throughput. The mass spectrometer was operated in the scan/selected ion monitoring (SIM) acquisition method, thus enabling the obtainment of qualitative and (highly sensitive) quantitative data. The separation of FAMEs was obtained in about 11 min by using a micro-bore column of dimensions 15 m x 0.10 mm ID x 0.10 mu m d(f) with a polyethylene glycol stationary phase. The novelty of the research involves reducing analysis time by using the novel fast GC-MS method with increased identification reliability and sensitivity in a single chromatographic run. With regard to the figures of merit, linearity, accuracy, and limits of detection (LoD) and quantification (LoQ) were determined. Specifically, regression coefficients were between 0.9901 and 0.9996; the LoDs ranged from 0.05 to 1.02 mu g g(-1) for the blood analysis method, and from 0.05 to 0.26 mg g(-1) in the case of the dietary supplement approach. With respect to LoQs, the values were in the ranges of 0.15-3.39 mu g g(-1) and 0.15-0.86 mg g(-1) for blood and dietary supplements analysis methods, respectively. Accuracy was evaluated by analyzing certified reference materials (human plasma, fish oil).File | Dimensione | Formato | |
---|---|---|---|
61_ABC_plasma_2022.pdf
solo utenti autorizzati
Descrizione: Versione elettronica
Tipologia:
Versione Editoriale (PDF)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
2.33 MB
Formato
Adobe PDF
|
2.33 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
3304950_removed.pdf
solo utenti autorizzati
Descrizione: Versione a Stampa
Tipologia:
Versione Editoriale (PDF)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
5.9 MB
Formato
Adobe PDF
|
5.9 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.