The present contribution is focused on the measurement of the analytical sensitivity attained in untargeted/targeted MS/MS experiments, performed using flow-modulator comprehensive 2- and 1-D gas chromatography. The comprehensive 2-D experiment was performed by diverting part of the high flow (circa 80%) to flush the accumulation loop (about 28 mL/min) to waste, to reduce the gas flow entering the ion source. 1-D analyses were performed through: I) unmodulated and II) single column applications. An equivalent temperature program was applied in the modulated and unmodulated analyses, while a faster one was employed in the single column one. In all application types, the (same) triple quadrupole instrument was operated in the full-scan and multiple reaction monitoring modes. A genuine sweet orange oil and the same sample spiked with 20 phytosanitary compounds were employed to reach the research objective. The results highlight the problems related to the flow modulation–mass spectrometry combination. Specifically, it was found that sensitivity was on average 3–4 times higher in unmodulated and optimized single-column applications.

A direct sensitivity comparison between flow-modulated comprehensive 2- and 1-D GC in untargeted and targeted MS based experiments

TRANCHIDA, Peter Quinto;FRANCHINA, FLAVIO ANTONIO;ZOCCALI, MARIOSIMONE;BONACCORSI, Ivana Lidia;CACCIOLA, FRANCESCO;MONDELLO, Luigi
2013-01-01

Abstract

The present contribution is focused on the measurement of the analytical sensitivity attained in untargeted/targeted MS/MS experiments, performed using flow-modulator comprehensive 2- and 1-D gas chromatography. The comprehensive 2-D experiment was performed by diverting part of the high flow (circa 80%) to flush the accumulation loop (about 28 mL/min) to waste, to reduce the gas flow entering the ion source. 1-D analyses were performed through: I) unmodulated and II) single column applications. An equivalent temperature program was applied in the modulated and unmodulated analyses, while a faster one was employed in the single column one. In all application types, the (same) triple quadrupole instrument was operated in the full-scan and multiple reaction monitoring modes. A genuine sweet orange oil and the same sample spiked with 20 phytosanitary compounds were employed to reach the research objective. The results highlight the problems related to the flow modulation–mass spectrometry combination. Specifically, it was found that sensitivity was on average 3–4 times higher in unmodulated and optimized single-column applications.
2013
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11570/2557427
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 17
social impact